Sunday, December 22, 2024

Emulate, Inc. Launches Chip-R1 for Enhanced Biological Modeling

Emulate, Inc., the leading provider of next-generation in vitro Organ-Chip models, announced the release of its new Chip-R1 Rigid Chip, designed to minimize drug absorption and enhance biological modeling. Constructed using low-drug-absorbing plastics, Chip-R1 builds upon the core microfluidic design of Organ-Chips, offering researchers greater precision in predicting human drug responses.

In addition to enhancing the accuracy of Organ-Chip experiments for ADME and toxicology applications, the new features of Chip-R1 can improve research across many other avenues. The modified design of the vascular channel enables physiologically relevant levels of shear stress, which is critical for vascular biology applications such as immune cell recruitment. Additionally, this model features a thinner membrane with smaller pores, enabling enhanced cellular crosstalk and better approximations of the in vivo milieu.

Novel features of Chip-R1 include:

  • Minimally drug-absorbing chip materials for accurate compound testing
  • Better approximation of the in vivo microenvironment through increased shear stress in the vascular channel
  • A preactivated tissue culture membrane to simplify the user workflow
  • Reduced imaging distance, expanding compatibility for microscopy

Also Read: BioSkryb Genomics Joins Human Cell Atlas to Enhance Single-Cell Technology

“This represents a step change in Emulate’s Organ-on-a-Chip technology, enabling customers to test compounds that were previously not addressable,” said Danny Levner, PhD, Chief Technology Officer at Emulate. “With its low-drug-absorbing properties, Chip-R1 is well suited for drug development applications like pharmacokinetics and pharmacodynamics, where consistent and predictable drug exposure is critical.”

Chip-R1 retains much of the same microfluidic architecture of the Chip-S1® Stretchable Chip, including co-culture to model the tissue-tissue interface, independent perfusion of the apical and basal channels, and compatibility with Emulate’s instrumentation hardware. With a new polycarbonate tissue culture membrane, Chip-R1 is better suited for organ models that do not require mechanical stretch to mimic physiological functions like peristalsis, such as liver and kidney.

“Chip-R1 showcases the continued evolution of our innovative consumables portfolio. With improved detection of hepatotoxicity compared to Chip-S1, it broadens the use of Organ-Chips to scientists who were previously concerned about how potential drug absorption impacts the accuracy of detecting drug-induced toxicity of small molecule lipophilic drugs,” said Lorna Ewart, PhD, Chief Scientific Officer at Emulate.

SOURCE: Businesswire

Subscribe Now

    Hot Topics